产品详情
产品参数(Product Specifications)
Assay TypeSandwich-ELISAAnalyteAAV8Format96TReactivity/Regulatory StatusRUOSensitivity≤100ng/mLStandard Curve Range0.938 ng/mL-60 ng/mLAssay Time3 hr 20 minSuitable Sample TypeFor the quantitative determination of anti-AAV8 antibodies in serum.Sample volume100 uL产品概述(Product Overview)
Anti-AAV8 Antibody ELISA Kit is based on the sandwich-ELISA method and is used to detect and quantitatively determine the Anti-AAV8 Antibody in serum. The kit is designed to provide reliable solutions for the immunogenicity studies and enrollment screening of AAV gene therapy products.
重构方法(Reconstitution)
Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.
存储(Storage)
1. Unopened kit should be stored at 2℃-8℃ upon receiving.
2. Find the expiration date on the outside packaging and do not use reagents past their expiration date.
3. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.
组分(Materials Provided)
IDComponentsSizePAV008-C01Pre-coated AAV8 Capsid Protein Microplate1 platePAV008-C02Anti-AAV8 Antibody Standard2.5 μgPAV008-C03Biotin-AAV8 Capsid Protein1 μgPAV008-C04Streptavidin-HRP10 μgPAV008-C0510xWashing Buffer50 mLPAV008-C062xDilution Buffer50 mLPAV008-C07Substrate Solution12 mLPAV008-C08Stop Solution7 mL质量管理控制体系(QMS)
数据展示
典型数据-Typical Data
Please refer to DS document for the assay protocol.
Detection of anti-AAV8 antibodies by sandwich-ELISA Assay.
Immobilized AAV8 Capsid Protein can bind Anti-AAV8 Antibody in 1:50 human serum, and then add Biotin-AAV8 Capsid Protein. Detection was performed using Streptavidin-HRP with sensitivity of 46.9 ng/mL.The specific binding of PAV-A008 to Anti-AAV3/5/9 antibody was detected. The results showed that PAV-A008 only binds specifically to Anti-AAV8 antibody.
批内差异(Intra-Assay Statistics)
Three samples of known concentration in blank human serum were tested six times on one plate to assess intra-assay precision, Intra-Assay Precision CV≤15%.
Three samples of known concentration in blank mouse serum were tested six times on one plate to assess intra-assay precision, Intra-Assay Precision CV≤15%.
批间差异(Inter-Assay Statistics)
Three samples of known concentration in blank human serum were tested in six separate assays to assess inter-assay precision, Inter-Assay Precision CV≤15%.
Three samples of known concentration in blank mouse serum were tested in six separate assays to assess inter-assay precision, Inter-Assay Precision CV≤15%.